This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). Addressed an issue where the server might become unresponsive after a user has repeatedly entered and incorrect Power-On or Administrator Password. This issue did not affect servers configured for UEFI Boot Mode. The URL describing the network (HTTP or FTP) location of the startup script can be configured in the System Utilities /Platform Configuration (RBSU), under the Embedded Shell menu. Added support for a webclient command in the Embedded UEFI Shell. Mitigations for Variant 1 (Spectre) and Variant 3 (Meltdown) vulnerabilities require only OS updates and are not impacted. Addressed an issue where Processor Core Disable may not function properly, such as disabling the wrong number of cores, when Intel Xeon E5 v4 processors are installed in the system. This issue does not affect any other processor models. End of Life (EOL) means that the HP ProLiant DL380 Gen9 will no longer be sold, marketed, or updated it after the EOL date. Addressed an issue where an erroneous 312 - HP Smart Battery error message would be displayed and logged to the Integrated Management Log (IML) on the first boot after the system battery was removed from the server. This could take up to 3 minutes, depending on your computer and connection speed. Technical data is gathered for the products supported by this tool and is used to identify products, provide relevant solutions and automatically update this tool, to improve our products, solutions, services, and your experience as our customer. Â, End User License Agreements:OpenSSL License Agreement, Version 0.9.8UEFI EDK2 License. Why Should we Patch ROM Firmware? Addressed an issue where the system would continue to run (server did not perform a Blue Screen or reset as expected) when a Non Maskable Interrupt (NMI) occurs when using Microsoft Windows 2008 or Microsoft Windows 2008 R2 when Processor x2APIC Support is configured to Enabled (the default value). How does HP install software and gather data? The user can now optionally select to use the DUID-LLT as the unique identifier for PXE Boot. HPE ProLiant DL Server Series. By default, the time is formatted for Coordinated Universal Time (UTC). Addressed an issue where the System Utilities BIOS/Platform Configuration (RBSU) USB Boot Options setting may not properly allow the server to boot from the internal SD card before a USB key when SD is higher in the priority list. 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Save your personal devices and preferences, Managing contracts and warranties for your business, For Samsung Print products, enter the M/C or Model Code found on the product label. Locate the file in your browser window, and double-click to begin installing. This issue does not impact systems configured for UEFI Boot Mode. This issue is NOT unique to HP servers. For general questions, email us at hpestore.quote-request@hpe.com When this condition is detected, a new Integrated Management Log (IML) message will be logged indicating a "High rate of corrected memory errors, performance may be degraded". Note that the Integrated Lights-Out (iLO) Firmware had a similar issue. If you have the SPP version, please share so that we can share the content report which gives the detailed information of respective SPP. Please try again later. This issue was seen with a Brocade network adapter but could be seen with other adapters. Insert this USB Key into the USB Key port of the system to be updated and power the system on to boot to the USB Key. This could result in one or more of the GPUs experiencing a "Yellow Bang" under a Microsoft operating system. Addressed an issue where the system may not properly respond to error events from devices attached to certain PCI Express root ports. Addressed an extremely rare issue where the server may become unresponsive due to a Non Maskable Interrupt (NMI) when performing a shutdown or startup from an Operating System. These issues did not affect systems configured in UEFI Boot Mode. Addressed an issue where the +/- keys in the BIOS/Platform Configuration (RBSU) Boot Options menu were not functioning properly when configuring the server through a BIOS Serial Console Session. These cookies are necessary for the website to function and cannot be switched off in our systems. This page requires Javascript. The proloants are are actual by firmware. Addressed an issue where the UEFI iSCSI Software Initiator boot option IPv6 address cannot be configured using the HP RESTful API. These new options allow the user to configure the number of boot targets that are listed per storage controller in the UEFI Boot Order. Addressed an issue where Linux dmesg might report a USB error message such as "EHCI: BIOS handoff failed" when the system was configured in Legacy Boot Mode. Addressed an issue in the HP RESTful API data model with the reporting of "EmbSasXBoot" and "SlotXStorageBoot" properties in the HpBiosMappings resource. Addressed an issue where the system may display a Red Screen error and become unresponsive during boot when the Embedded User Partition or Virtual Install Disk are enabled or if a USB storage device is installed when the server is configured for Legacy Boot Mode. HPE OneView is your infrastructure automation engine, built with software defined intelligence and a unified API, that when combined with HPE OneView Global Dashboard software, gives you the ability to both manage and update all your HPE servers, storage and fabric across a single user interface. Addressed an issue where the system may display a Red Screen error and become unresponsive from the Embedded UEFI Shell when interrupting the ping command via a CTRL-C key press. Disabling this option has been shown to provide performance benefits in a very small subset of configurations including certain Infiniband configurations that require a balanced mix of read and write traffic as well as configurations with multiple x16 devices that utilize the max bandwidth of the PCI-e bus. Dl380 gen9 server. Â
You only need to do this once to guarantee a faster support experience at any time. How to Update HP Device Drivers Quickly & Easily. The DL380 provides the next-level performance and expansion options youâve come to ⦠This issue is not unique to HPE servers. Added support for self-links in these resources. This option provides enhanced memory availability and resiliency but requires additional memory be installed to achieve the same amount of memory available to the operating system. The user can still control the priority of the boot entries of individual USB devices in the UEFI Boot Order list. Hp Proliant Dl380 Gen9 Firmware Download. It is important to update the firmware (Also called â flashing the ROM) as part of the regular server maintenance. Addressed an issue where certain optional PCIe video adapters would fail to work properly when using a Linux operating system. Added support for additional Storage Options to BIOS/Platform Configuration (RBSU). This is the initial version of the firmware. The HPE ProLiant DL380 Gen9 Server delivers the best performance and expandability in the Hewlett Packard Enterprise 2P rack portfolio. Gen9 ISO will have files related to Gen9 and previous versions. This allows for easier parsing of the command output using Shell scripts. This product detection tool installs software on your Microsoft Windows device that allows HP to detect and gather data about your HP and Compaq products to provide quick access to support information and solutions. By choosing to install, I agree to HPâs terms and conditions on data collection. HPE provides customized ESXi Images that allow you to install ESXi on HPE ProLiant Servers. Let HP identify any out-of-date or missing drivers and software. Addressed an issue where the System Utilities BIOS/Platform Configuration (RBSU) Dynamic Power Savings Mode Response Option when configured for Slow Mode may not efficiently switch processor performance modes resulting in lower than expected performance. Selected operating system:
How does HP use product data collected with this service? Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. It can also be used to download ISO CD/DVD images and mount them in memory as RAM disks. Addressed an issue where optical drives were not properly reported in the server One Time Boot Menu when the HP Smart Array B140i Smart Array controller is enabled. Addressed an issue where the server could become unresponsive during boot or from the Embedded UEFI Shell when a Block I/O device such as a USB key or hard drive has a corrupt FAT32 file system. Added support for Intel Trusted eXecution Technology (TXT). HP USB FLASH DRIVE . The HP ProLiant DL380 Gen9 Server delivers the best performance and expandability in the HP 2P rack portfolio. RECOMMENDED * System ROMPaq Firmware Upgrade for HPE ProLiant DL360 Gen9/DL380 Gen9 (P89) Servers (For USB Key-Media) - 2.76_10-21-2019 (A) Nov 13, 2019 Will start by installing the BIOS via USB key. Addressed a rare intermittent issue where the F10 prompt to enter Intelligent Provisioning is not displayed. The iSCSI Software Initiator boot support can be enabled on any network card that is in Ethernet mode. No branding changes were made that could impact software running on the system. Hewlett packard enterprise, dl380 generation9 gen9, dl380 generation9 gen9 overview, oneview global dashboard. This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. Proceso de actualización de firmare de los servidores, en este caso se ha realizado el update de versión de sistema operativo Hp proliant dl380 ⦠Â
Addressed an issue where the Integrated Management Log (IML) or operating system log would report multiple error entries when an Non-Maskable Interrupt (NMI) occurs. Attempting to boot from the Generic USB Boot entry will result in attempting all UEFI bootable USB devices that are available in the system. Addressed an issue where the system would become unresponsive during boot and display a NMI error when configured with an optional PCI Express device supporting older versions of the PCI Express specification. Addressed an issue where the system might become unresponsive during boot when an unsupported memory configuration is installed on processor 2. The hp proliant dl380 gen9 server was released a few weeks ago in late. Please verify your product is powered on and connected, then try again in a few minutes. The PC you are currently using does not match the PC you have selected. Previous revisions of the System ROM defaulted to scanning all targets. Addressed an issue where the System Utilities BIOS/Platform Configuration (RBSU) option for Embedded UEFI Shell Auto Startup Script Network Location does not accept an NSH file name containing upper case characters. Industry standard SMBIOS tables were NOT updated to reflect Hewlett Packard Enterprise branding. This new option is applicable only in UEFI Boot Mode and might be configured from the HP RESTful API or the System Utilities BIOS/Platform Configuration (RBSU). Smart Update Manager (SUM) is an innovative tool for keeping the firmware, drivers and system software of HPE server infrastructure and associated options up ⦠Addressed an issue where the system may become unresponsive during system boot when a USB-based UPS is attached to the server USB ports. With previous revisions of the System ROM, the system health LED would not return to GREEN until after a reboot when a failed power supply is replaced. See your browser's documentation for specific instructions. Addressed an issue where the system may experience a Linux kernel panic when booting from a SATA optical drive attached to the embedded SATA controller when the SATA controller is configured for Dynamic Smart Array B140i support. This option controls how the system date and time is stored in the Real Time Clock and presented to the operating system. Added support for loading the Embedded UEFI Shell Auto-Startup script from the network in addition to physical/virtual media. Intel has only seen this under synthetic testing conditions and is not aware of any commercially available software exhibiting this behavior. This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system and/or hypervisor updates, provides mitigation for a new group of side channel vulnerabilities known as Microarchitectural Data Sampling (MDS). This includes support for mitigating the following vulnerabilities: CVE-2018-12126 â Microarchitectural Store Buffer Data Sampling, CVE-2018-12130 â Microarchitectural Fill Buffer Data Sampling, CVE-2018-12127 â Microarchitectural Load Port Data Sampling, and CVE-2019-11091 â Microarchitectural Data Sampling Uncacheable Memory. These issues are not unique to HPE servers. Addressed various issues where network boot support options might not be applied properly from HP Virtual Connect or HP OneView. First, install HP Support Solution Framework. This includes the latest list of revoked certificates. Updated the HP RESTful API HP BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options. - HPE ProLiant DL380 Gen9 Server - QuickSpecs - c04346247.pdf To ensure the integrity of your download, HPE recommends verifying your results with
0. This issue does not occur when booting in UEFI Boot Mode. This issue only affects servers configured in Legacy Boot Mode. Addressed an issue where the server may display a Red Screen error and become unresponsive during boot when more than 256 hard drives are attached to a storage controller. Â These security vulnerabilities are not unique to HPE servers. We will offer drivers and other solutions in this OS first. Obtain a formatted USB Key media. This revision of the System ROM includes the latest revision of the Intel microcode which addresses an issue where the system could experience an unexpected reset or shutdown with no errors logged to the Integrated Management Log (IML). Addressed an issue where the system may fail to boot a Linux Operating System when using serial console redirection when the physical Serial Port is disabled and the iLO Virtual Serial Port is enabled. This may help resolve issues of intermittent connection drop during an iSCSI boot. Reduced boot time when the Dynamic Smart Array B140i RAID is enabled. This new entry is used as a place holder for any USB device that is bootable in UEFI. This issue does not impact systems configured with other memory configuration including 64GB LRDIMM with less than 3 DIMMs Per Channel. HP Enterprise (HPE) supports servers, switches, routers, and tape drives. Addressed an issue where a server configured with a Trusted Platform Module (TPM) and Microsoft Windows 2012 R2 BitLocker might incorrectly prompt the user for a recovery password following a warm reset. Enhancements:
This issue only affects systems configured in Legacy Boot Mode. 4. This issue does not impact systems configured for UEFI Boot Mode. Your session on HP Customer Support has timed out. Addressed an issue that may result in losing the existing UEFI iSCSI Software Initiator boot options if any of the connection parameters (LUN, Remote Port, IP address, login credentials) change. This issue does not impact servers with memory configured on multiple processors. In addition, added a new Firmware Information menu to System Information to provide a list of current firmware revisions for supported components. Addressed an issue where the server may fail to boot properly to a Windows Deployment Server (WDS) when configured for IPv6 network boot mode. Support for OHCI USB controllers should be available from operating system drivers when not in the pre-boot environment. Addressed an issue where the Administrator Password and Power-On Password were incorrectly allowed to be entered with a length of 32 characters with previous revisions of the System ROM. This issue does not impact systems configured with Intel Xeon E5 v3 processors. Added support for a new partitions command in the Embedded UEFI Shell. Here are the drivers available for your system. When the system time or time zone are changed, on reboot the system time might 'jump' by the current operating system time zone offset. Driver detection is now available for the desktop download experience. Addressed an issue where selecting "Erase User Defaults" (to erase user defined defaults) in BIOS/Platform Configuration (RBSU) does not take effect if the user also selected Restore Default System Settings or Restore Default Manufacturing Settings. Addressed an issue where the UEFI iSCSI Software Initiator boot options may become invalid if the DHCP server provides a new IP Address to a previously configured iSCSI boot option. Addressed an issue where the Date and Time may be set incorrectly when using the Date and Time option from the BIOS/Platform Configuration (RBSU) when the Daylight Savings Time option is enabled. HP ProLiant DL380 Gen 9 furnishes a high-performance rack solution. The iSCSI network settings can be configured in the new System Utilities BIOS/Platform Configuration (RBSU) iSCSI Boot Configuration menu, as well as using the HP RESTful API HpiScsiSoftwareInititiator resource type. Updated the HP RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options. The user can set the boot priority of this Generic USB Boot entry, and retain this priority for use with USB devices that might be installed in the future. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. Addressed an issue where the system may fail to boot from existing UEFI iSCSI Software Initiator boot options if the user changed the iSCSI Target IP address. The Boot from ISO support is currently limited to operating systems that have a self contained OS image (such as WinPE, mini Linux, or VMware ESX installer). Added support to detect and log when memory performance may be degraded due to a high rate of correctable memory errors. Addressed an issue where a system running a hypervisor-based operating system may become unresponsive when a guest operating system executes certain debug commands.
Added support for UEFI iSCSI Software Initiator boot functionality. Added support for a new restclient command in the Embedded UEFI Shell. Enhanced the System Utilities System Information and the Embedded UEFI Shell sysinfo command to provide additional details for the processor, memory, PCI subsections. Learn more at the Official Hewlett Packard Enterprise Website. 2. HPE ProLiant Gen9 Servers - Software and Driver Download. This revision of the System ROM includes the latest revision of the Intel microcode which addresses an issue where the system could experience an unexpected reset or shutdown with no errors logged to the Integrated Management Log (IML). This command can be used to view all available drive partitions. Addressed an issue where a system may become unresponsive when launching a guest operating system under a Hypervisor operating system such as Citrix or VMware when VT-d is enabled. If a 32 character Administrator Password or Power-On Password had been configured in the server, updating to this revision of the System ROM will no longer allow entering these passwords. This issue does not affect systems configured in Legacy Boot Mode. HPE ProLiant DL360/DL380 Gen9 System ROM - P89 Â. The DL380 Gen9 runs P440, P840, B140, H240 series controllers, which doesn't appear on the home page. Addressed an issue where the system might experience a Machine Check Exception under heavy stress conditions when configured with an Intel Xeon E5-2609 processor. Added support for HPE 128GB SmartMemory Load Reduced DIMMs (LRDIMMs). DRIVERS HP PROLIANT DL380 GEN9 ILO FOR WINDOWS. . The number of active cores would not be reported properly by some utilities. This issue does not impact systems configured for UEFI Boot Mode. Addressed an issue where uncorrectable Quick Path Interlink (QPI) errors would not be reported properly and logged to the Integrated Management Log. Addressed an issue where the UEFI or Legacy Option ROM for a PCIe adapter may not be properly executed when installed in certain slots. This could cause such issues as an inability to boot using the PCIe adapter. This issue was seen with a Brocade network adapter but could be seen with other adapters. Enhanced the UEFI Exception handler to provide extended debug and trace information when in a pre-OS environment. Addressed various issues with webclient and ftp commands in the Embedded UEFI Shell. HPE continues to offer post-warranty support, but Third-Party Maintenance (TPM) is available for most OEM equipment that is EOL. Addressed an issue that might result in the BIOS Console Redirection support using the Virtual Serial Port to become non-functional. Please wait, this may take a few momentsâ¦â Note: BIOS P89 v.2.40 is part of the HPE SPP from April 2017 (SPP 04/2017) my server is guaranteed and can not download ... there is a padlock ??? Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. Addressed an issue where the Administrator Password would not be properly configured from the Embedded UEFI Shell Sysconfig command. Addressed an issue where the server health LED may remain set in a degraded or failed state after an error event was resolved during server operation. By default, the system will use the server's Unique Universal Identifier (UUID). Addressed an issue where the server may become unresponsive when using the PING command from the Embedded UEFI Shell. Skip the confusion of sorting through all of our drivers and let us detect only the ones you need. This change only prevents the display of the erroneous message and does not impact USB functionality. This command can be used to download Active Health System (AHS) files. Note: HP ProLiant DL380 Gen 9 furnishes a high-performance rack solution. The boot to the SPP USB key and maybe select the interactive method so I can see what it tries to do. Added support for Trusted Platform Module (TPM) 2.0 Firmware flash updates. Addressed an issue where the ambient temperature reported by the system during server boot may report incorrectly. Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis. Addressed an issue where a server might not be able to properly boot Windows Server 2008 R2 when configured with an Optional Graphics Card or GPGPU. Detection completed. Added support to allow for the ROM Based Setup Utility (RBSU) Power Regulator setting to be set to Static Low or OS Control Mode when the Processor Power and Utilization Support was disabled. Addressed an issue where systems configured Intel Xeon E5-2600 v4 processors and 64GB LRDIMMs may experience a Machine Check Exception or NMI event when under heavy stress. Added support for a new ahsdownload command in the Embedded UEFI Shell. This option enables or disables the Advanced Encryption Standard Instruction Set. Known Issues: Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models. Please consult the following advisory for additional details. To address all cases of the F10 prompt not being displayed, also update the iLO Firmware to revision 2.02. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. This will take you to the Driver and Software page of the Product/Model. My opérating system is Enhanced the thermal solution to provide proper cooling for optional PCIe graphics and acceleration cards. A firmware update of the fibre channel controller might also be required to take full advantage of this feature. Addressed an issue where the SATA port numbers reported in the System Utilities BIOS/Platform Configuration (RBSU) would not properly match the port numbers reflected by labels on the system. Now we want to install them as a Win 2008 R2 server, but we cannot create a NIC teaming. HP supports printers, pc's, tablets and calculators . Addressed an issue where the system may become unresponsive and experience a Machine Check Exception or NMI under heavy stress conditions when configured with Intel Xeon E5-2600 v3 processors and 64GB LRDIMMs in a 3 DIMM Per Channel configuration. The network settings (DHCP or static IP) and boot file URL can be configured in the new System Utilities BIOS/Platform Configuration (RBSU) Pre-Boot Network settings menu. By default, the system will now only scan for Fibre Channel boot targets that are configured in each adapter.